- Product Categories
- Friendly Links
Information Name: | Intake duct relative humidity sensor |
Published: | 2015-03-17 |
Validity: | 8000000 |
Specifications: | 440 × 340 × 140mm |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | Description: JCJ200Y temperature measuring device is wet nine pure health technology to measure the humidity of ultra-high temperature above 150 ℃ under high temperature and developed a special measuring device wet. JCJ200Y temperature measuring device using wet nine pure health technology has JUCSAN independent core technology of? High-temperature wet sensation as the humidity sensor element, with fan cooling fan circulation processing, combined with years of practical experience in the field of high temperature measuring humidity, by cleverly conceived and science rigorous design, high temperature measuring humidity in the industry has opened up a new way to solve the many high wet practical problems can not be measured, the products have been widely used in the (150 ℃ ~ 600 ℃) of various areas of high temperature and humidity measurements. JCJ200Y temperature measuring device works briefly wet first temperature measuring device by circulating fan wet up to several hundred degrees the temperature of the gas pumped from a test environment in the pipe and high temperature measuring device connected to the wet, and then processed through fan cooling to the right temperature, and then measured gas sample is sent to a sealed interior (humidity sensor here), in the sampling indoor humidity measurement is completed, the last measured gas has returned to the original position, thus completing a humidity measurement. The entire measurement process is completely closed environment, in the absence of moisture loss situation, would not have a big impact and humidity measurements, the measured moisture and humidity in the original measured media is relatively close by analysis of the measured humidity can determine the size of the measured gas humidity, so as to achieve the purpose of measuring humidity. JUCSAN? Series transmitter uses the customer has been widely recognized in the form of a DC voltage or current output can be directly connected with nine pure health? Series secondary instrument or capture card. Applications: High Moisture-specific, reasonable design, stable performance, wide measuring range, long life, wide range of applications, can be customized for special applications. Textile industry, high-temperature drying, styling, materials and other high-temperature drying. Technical parameters: JCJ200Y temperature measuring device wet working power 12VDC ± 10% 12VAC ± 10% Power Requirements: 12V / 35Ma 24VDC ± 10% 24VAC ± 10% Power Requirements: 24V / 45mA fan working power 220VAC ± 10% Power: 50W temperature parameters temperature sensor Pt100 platinum resistance temperature measurement range (0 ~ 200) ℃ temperature compensation and humidity parameters humidity sensor JUCSAN @ humidity resistance operating temperature -40 ~ 150 ℃ reaction time (ta) typ <5s long-term stability of the typical 0.5% RH / Effective measurement range 10 ~ 95% RH (non-condensing) Measurement Accuracy ± 3% RH (20 ~ 90% RH, 20 ℃) ??measurement stability under normal condition, the drift is not greater than 1% RH output signal voltage signal 1, (0 ~ 5) VDC 2, (0 ~ 10) VDC 3, (0 ~ 1) VDC current signal 4, (4 ~ 20) mA (three-wire) 5, (0 ~ 10) mA 6, (0 ~ 20 ) mA 7, (4 ~ 20) mA (two-wire) Total Operating humidity: 5 ~ 90% RH (non-condensing) Temperature: (- 40 ~ 80) ℃ cold rolled steel spray machine Material Dimensions 440 × 340 × 140mm Weight Weight milky color installation screws load capacity Voltage Type: ≥1KΩ current type: 0 ~ 500Ω wiring diagram: Note: For non-isolated input signals of temperature and humidity table / PLC analog acquisition modules and other secondary instrument The signal "input -" may be in a terminal, you can simply take the "Power -" button. RT (Tout): Temperature signal output RH (Hout): humidity signal output VCC: Power supply, according to the needs of the optional 12V / 24V GND: DC to 12VDC: output signal (0-5) V output when the power supply 24VDC: Output signal is 4-20mA or 0-10mA or 0-20mA or 0-5 / 10V AC power supply when the selection: 24VAC signals are connected to the power supply + and - (wiring, regardless of the order) Output: "Power -" as a signal to It and the temperature signal, the voltage corresponding to the humidity between the signals is the humidity and temperature measurements. Note: For AC power supply, if it is a current sensor signal output, the output must be in the form of a three-wire system. Product appearance schematic: JCJ200Y Product Selection: JCJ200YS mouth wet T mouth temperature measuring device JCJ200Y temperature measuring humidity device port output signal S 1 = (0 ~ 5) VDC 2 = (0 ~ 10) VDC 3 = (0 ~ 1) VDC 4 = three-wire (4 ~ 20) mA 5 = (0 ~ 20) mA 6 = (0 ~ 10) mA 7 = wire (4 ~ 20) mA 9 = user-specified R2 = RS232 interface R4 = RS485 interface T mouth measured gas temperature (when production as a reference) 2 = (0-200) ℃ 2 = (0-300) ℃ 4 = (0-400) ℃ 5 = (0-500) ℃ 6 = (0-600 ) ℃ 9 = user-specified output signal Y N no temperature with a temperature signal output |
Admin>>>
You are the 5743 visitor
Copyright © GuangDong ICP No. 10089450, Beijing nine pure health Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5743 visitor
Copyright © GuangDong ICP No. 10089450, Beijing nine pure health Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility